Pagina 1 - Release 3.4

iConverter® GX/TM Media ConverterandNetwork Interface DeviceSTANDALONE AND PLUG-IN MODULEUSER MANUALRelease 3.4

Pagina 2 - Table of Contents

3.2.2.5 SW5 - UTP 10/100 Auto/Manual Crossover “AX/MANX”The GX/TM features 10/100 Auto Crossover, which allows it to connect to a switch or a workstat

Pagina 3 - 1.1 GENERAL DESCRIPTION

3.3 INSTALLING PLUG-IN MODULES AND CONNECTING CABLESPIa. Carefully slide the module into an open slot in the chassis. Align the module with the insta

Pagina 4 - 2.1.2 UTP and Fiber Ports

3.4 CONFIGURE THE MODULE VIA COMMAND LINE INTERFACE PI SATo configure, attach the GX/TM to a DB-9 serial (RS-232) equipped computer with terminal em

Pagina 5 - 3.1 OVERVIEW

The Management Options screen will be displayed.PI SAManagement Options iConverter, Serial Agent Network Management 1: Chassis and Module Management

Pagina 6 - (Up/Down)

Page 143.4.1 Setting IP and Control PreferencesAn IP address is required for the SNMP manager to address the GX/TM. The factory default setting is192

Pagina 7 - UTP Port Configuration Matrix

3.4.1.2 Setting IP Parameters as DHCP ClientTo configure the IP automatically as a DHCP client, select 9 from the Management Options screen. TheOther

Pagina 8 -

To set the Chassis Number, select 4 at the IP and Control Preferences screen, press <ENTER> and followthe instructions to enter the chassis numb

Pagina 9

PI SAIP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1

Pagina 10 - 3.2.2.7 SW7, SW8 - Reserved

Page 18PI SA SNMP Preferences Screen iConverter, Serial Agent Chassis Number = 1 SNMP Engine ID 80001CAE

Pagina 11

To set User 1 security, select 10 at the SNMP Preferences screen, press <ENTER> and then follow thescreen prompts. To set the User 2 security,

Pagina 12 - Serial Connector Pin Outs

Page 2Table of Contents1.0 Overview ...

Pagina 13

Page 203.4.3 Management Processor VLAN SupportThe GX/TM Management Processor can independently transmit and receive Management Data with anIEEE 802.1Q

Pagina 14

3.4.4 Enabling/Disabling Soft-switch ReloadThe Soft-switch Reload function controls the configurations of the GX/TM and other iConverter modulesmanage

Pagina 15

3.4.5 Access the GX/TM RemotelyRemote access to the GX/TM is provided via SNMP, Telnet, FTP or an external serial modem connected tothe Serial Console

Pagina 16

PI SAIP and Control Preferences Screen iConverter, Serial Agent 1: Set IP 192.168.1.220 2: Set Subnet Mask 255.255.255.0 3: Set Gateway 192.168.1.1

Pagina 17

When the upload is complete, the GX/TM displays the update status and then automatically restarts withthe newly loaded firmware.3.4.5.4 Updating the G

Pagina 18

3.5 VERIFY OPERATION PI SAOnce the module has been installed and configured, per Sections 3.2 - 3.4, verify the module is operationalby viewing the

Pagina 19

4.0 DETAILED MODULE CONFIGURATION PI SA4.1 OVERVIEWThe GX/TM has module parameters that require configuration depending on the application. The Mod

Pagina 20

PIChassis View 19 Slot iConverter, Serial Agent Chassis Number = 1 Slot Model Type | Slot Model Type 1 8000-0 NMM | 16 N/A 2 8903-1 10/100

Pagina 21

PIModule - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Switch ON Condition OFF Condition H/W

Pagina 22 - or third-party

4.2 MODULE MANAGEMENT MODEFrom the Module configuration screen, the management mode can be changed. Select option 18 to changethe mode. The manageme

Pagina 23

1.0 OVERVIEWThis document describes the installation and configuration of the iConverter GX/TM standalone NetworkInterface Device and plug-in modules.

Pagina 24

4.3 PORT CONFIGURATIONThe Port configuration screen provides access to the port level configuration parameters, such as, PortAccess, SFP information,

Pagina 25 - 3.5 VERIFY OPERATION

4.3.1 Port AccessThe Port Access option allows the ports to be disabled/enabled while maintaining the port configurationand network linkTo configure

Pagina 26 - 4.1 OVERVIEW

PI SASFP Information - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 2 Model Number = 8939-0 Port =

Pagina 27

4.3.3 802.3ah ParametersThe 802.3ah parameters can be monitored and/or configured in the 802.3ah Control screen.• 802.3ah OAM State - The 802.3ah OAM

Pagina 28

“Incomplete”, Discovery is in process, but is not yet completed.• Multiplexer State - Indicates the Multiplexer state (“Discard”, “Forward” or “Unknow

Pagina 29 - 4.2 MODULE MANAGEMENT MODE

4.3.4 802.3ah Events802.3ah events can be accessed by selecting options 8 from the Port configuration screen.PI SA802.3ah Event - iConverter GX/TM iC

Pagina 30 - 4.3 PORT CONFIGURATION

4.3.5 Port VLANThe flow of data on the module is controlled by configuring the Port VLAN settings. The block diagramillustrates the flow of both the m

Pagina 31 - 4.3.2 SFP Information

PIModule - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Port VLAN Path Setup Slot Number = 2

Pagina 32

4.3.6 Tagged VLANThe GX/TM supports the IEEE 802.1Q tag VLAN packet tagging and un-tagging and the 802.1p Quality ofService priority standards.Tag con

Pagina 33 - 4.3.3 802.3ah Parameters

PITag VLAN Control - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 2 Model Number = 892

Pagina 34

2.0 PORT STRUCTURE2.1 OVERVIEWThe front panel of the GX/TM provides access to the management (serial console), UTP and fiber ports.The fiber port wil

Pagina 35 - 4.3.4 802.3ah Events

4.3.7 VLAN Membership TableThe VLAN Membership Table lists the permitted VLAN ID (VID) for each egress port on the module.Only packets that are assign

Pagina 36 - 4.3.5 Port VLAN

PIMembership Entry - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8923-1

Pagina 37

PIMembership Entry - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8923-1

Pagina 38 - 4.3.6 Tagged VLAN

4.3.8 cNode LoopbackThe GX/TM has implemented Iometrix cNode Level 1 agent for testing performance metrics. The agentrecognizes measurement packets an

Pagina 39

PI SAPort StatisticModule - iConverter GX/TM iConverter, Serial Agent Identifier - Chassis Number = 1 Slot Number = 1 Model Number = 8923-1

Pagina 40 - 4.3.7 VLAN Membership Table

5.0 GX/TM SPECIFICATIONSPlug-in Module Standalone Tabletop Standalone Wall-MountDescription 10/100/1000BASE-T UTP to 1000BASE-X Fiber Media Converter

Pagina 41

6.0 TROUBLESHOOTING GUIDE6.1 OVERVIEWThe GX/TM module has several LED indicators available to assist in the determination of problems. Referto Sectio

Pagina 42

6.1.3 UTP IssuesProblem:The UTP link LED does not illuminate after installation is complete.Possible Causes:A. Confirm that the UTP cable is connected

Pagina 43 - 4.3.9 Port Statistics

7.0 WARRANTYThis product is warranted to the original purchaser against defects in material and workmanship for aperiod of TWO YEARS from the date of

Pagina 44

19-Module Chassis 5-Module Chassis 2-Module Chassis1-Module Redundant Chassis3.0 INSTALLATION PROCEDURE3.1 OVERVIEWThe following steps outline the

Pagina 45 - 5.0 GX/TM SPECIFICATIONS

3.2 CONFIGURING DIP-SWITCHES PI SAThe GX/TM plug-in module has two board-mounted DIP-switches. The standalone unit has one bank ofDIP-switches. Th

Pagina 46 - 6.1.2 Fiber Issues

NOTE: When the fiber optic port operates in Auto-Negotiation mode, the port advertises for Pause.When the fiber optic port operates in Manual mode, P

Pagina 47 - 6.1.3 UTP Issues

3.2.1.3 SW3 - UTP Speed Gigabit/10-100 “1000/10-100”When the “1000/10-100” DIP-switch is in the “1000” position (factory default), the UTP always oper

Pagina 48

3.2.2 Board-Mounted Bank 2 Settings PI SADIP-switch Bank 2 is available on both the plug-in and standalone modules.PI SASwitch Left (Factory Defaul